The DC/AC inverters and systems are adapted to fixed installations also in heavy industry, power industry and fixed railway axis installations. They are not adapted for mobile applications.

Enedo use two basic Inverter module concepts
DAC6000 DC/AC inverter 800 - 1500 VA per module
DC-AC inverters are available for input/battery voltages 24, 48/60, 110/125 and 220 Vdc
with programmable 230 Vac 50 Hz output.
There are two basic modules:
1. 14 TE plug-in module in a 6U 19" sub rack system, as shown on the left.
2. Stand-alone module that can be mounted on wall or in 2U 19" rack.
These can be supplemented with automatic by-pass, manual switch and fuse distribution.
Modular power convertion architecture 1 - 24 kVA
Configuration as 1-phase or 3-phase systems, with or without true redundance; hot swapable.
The cooling configuration can be natural convection or fan cooling
Contact us for more information: https://www.polyamp.com/contact
Powernet DAC6000 Dual
Inverters made for telecom 48 / 60Vdc voltage, 115/230 Vac sine wave output voltage.
The base is 2x 1.5U 19" rack unit, are stackable and can be configured N + 1, also provide system power from 1 kVA to 30 kVA.
DC/AC inverter one and three phase
A module can provide between 1000 - 1500 VA or 600 W - 1200 W and can, with parallel connection, reach up to 30 kVA with one phase or three phases output.
A 6U rack has room for 6 modules which can be 1-6 inverters, a 6 kVA by-pass module and a manual switch with 3 distribution outputs. The devices can be remotely monitored locally or via Internet. The systems can be configured as N + 1 redundancy.
AC/AC Static Switch MBP Series
An AC/AC UPS system uses mostly AC directly from the grid in normal mode. The inverter system is dormant/standby and intervenes at power outages. The static switch ensures that switching between the networks is smooth and controlled without interruption.
DAC60000 Dual Inverter Systems
The DUAL Inverter System is a redundant, fault tolerant system, that provides an optimal solution when continuous operation and long battery service life is required. The systems have a modular construction and fit in standard 19″ racks and cabinets.
Contact us for more information: https://www.polyamp.com/contact
Key features | Applications |
Scalable power range 1-30kVA | Power transmission critical control circuits |
1-phase and 3-phase systems | Oil and Gas industry AC backup |
DC input voltage versions 48/60V | Industrial UPS systems |
True sinewave AC output | Telecom backup supply |
Hot swappable, n+1 redundancy | Data-Center UPS systems |
SNMP and relays for remote access | Railway track side information system’s backup supply |
Field proven reliability |